Line 258: | Line 258: | ||
* The relative humidity suddenly was lower than during any test before. Usually varying from 45 to 60% it suddenly never measured a value over 40% even when placed in rooms with higher humidity. | * The relative humidity suddenly was lower than during any test before. Usually varying from 45 to 60% it suddenly never measured a value over 40% even when placed in rooms with higher humidity. | ||
As the MQ135 heats up significantly when in use this might be an explanation for the changed results of the DHT11. To test that the MQ135 was removed from the breadboard to eliminate the suspected interference. The DHT11 still measured temperatures that were unrealistic. Right next to an open window and an outside temperature of 20°C the sensor showed a temperature of 25°C. Even with the expected margin of error that measurement is not reasonable. The humidity measurements seemed to improve, returning to their previous range between 45 and 60%.\\ | As the MQ135 heats up significantly when in use this might be an explanation for the changed results of the DHT11. To test that the MQ135 was removed from the breadboard to eliminate the suspected interference. The DHT11 still measured temperatures that were unrealistic. Right next to an open window and an outside temperature of 20°C the sensor showed a temperature of 25°C. Even with the expected margin of error that measurement is not reasonable. The humidity measurements seemed to improve, returning to their previous range between 45 and 60%.\\ | ||
- | Additionally, | + | Additionally, |
+ | <code c++> | ||
+ | #include " | ||
+ | void setup (){ | ||
+ | Serial.begin (9600); | ||
+ | } | ||
+ | void loop() { | ||
+ | MQ135 gasSensor = MQ135(A0); // Attach sensor to pin A0 | ||
+ | float rzero = gasSensor.getRZero(); | ||
+ | Serial.println (rzero); | ||
+ | delay(1000); | ||
+ | } | ||
+ | </ | ||
+ | |||
+ | Lastly, the sensitivity of the sensor module was adjusted by turning the on-board potentiometer on the back of the sensor module. With each change in sensitivity, | ||
=====Conclusion and Outlook===== | =====Conclusion and Outlook===== | ||
All in all, the system is functional. The communication between the sensors, the microcontroller and the LCD is working. It is unsure how accurate the obtained measurements are but as it is the system could be used as tool to give meaningful information and improve indoor air quality.\\ | All in all, the system is functional. The communication between the sensors, the microcontroller and the LCD is working. It is unsure how accurate the obtained measurements are but as it is the system could be used as tool to give meaningful information and improve indoor air quality.\\ | ||
Line 265: | Line 279: | ||
=====References===== | =====References===== | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ | * https:// | ||
+ |
amc2022/groups/start.txt · Last modified: 2022/09/10 23:57 by emilie001