User Tools

Site Tools


eolab:dieter:sensoren:sc-s2101

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
eolab:dieter:sensoren:sc-s2101 [2025/02/10 11:56] – created henrik.schoofseolab:dieter:sensoren:sc-s2101 [2025/02/10 12:10] (current) – [Datenblatt] henrik.schoofs
Line 1: Line 1:
 ====== SenseCap S2101 ====== ====== SenseCap S2101 ======
 +
 +===== Daten-Felder in der Datenbank =====
 +==== Eigene ====
 +^ field            ^ Daten-Typ  ^ Beschreibung - Bereich  ^ Beschreibung - Genauigkeit   ^ Beschreibung - Genauigkeit      ^
 +| air_humidity     | double     | 0 to 100 %RH            | ±1.8 %RH                     | long-term drift <0.25 %RH/year  |
 +| air_temperature  | double     | -40 to +85 °C           | ±0.2 °C                      | long-term drift <0.03 °C/year   |
 +
 +
 +==== LoRaWAN ====
 +{{page>eolab:dieter:sensoren:typ:lorawan&noheader}}
 +
 +
 +==== SenseCap ====
 +{{page>eolab:dieter:sensoren:typ:sensecap-lorawan&noheader}}
 +
 +
 +===== Datenblatt =====
 +{{pdfjs 75%,500px>:eolab:dieter:sensoren:sensecap_s2101_datasheet.pdf}}
 +
 +Datenblatt von [[https://solution.seeedstudio.com|SenseCAP]]
 +
eolab/dieter/sensoren/sc-s2101.1739185007.txt.gz · Last modified: 2025/02/10 11:56 by henrik.schoofs