User Tools

Site Tools


eolab:dieter:sensoren:sc-s2103

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
eolab:dieter:sensoren:sc-s2103 [2024/10/15 18:16] – created jan.sonntageolab:dieter:sensoren:sc-s2103 [2025/01/07 18:52] (current) jan.sonntag
Line 1: Line 1:
 ====== SenseCap S2103 ====== ====== SenseCap S2103 ======
 +
 +===== Daten-Felder in der Datenbank =====
 +==== Eigene ====
 +^ field            ^ Daten-Typ  ^ Beschreibung - Bereich  ^ Beschreibung - Genauigkeit   ^ Beschreibung - Genauigkeit      ^
 +| air_humidity     | double     | 0 to 100 %RH            | ±1.8 %RH                     | long-term drift <0.25 %RH/year  |
 +| air_temperature  | double     | -40 to +85 °C           | ±0.2 °C                      | long-term drift <0.03 °C/year   |
 +| co2              | double     | 400 to 10000 ppm        | 400 to 5000 ppm: ±(30+3%MV)  | 5000 to 10000 ppm: ±10%MV       |
 +
 +==== LoRaWAN ====
 +{{page>eolab:dieter:sensoren:typ:lorawan&noheader}}
 +
 +==== SenseCap ====
 +{{page>eolab:dieter:sensoren:typ:sensecap-lorawan&noheader}}
 +
 +===== Datenblatt =====
 +{{pdfjs 75%,500px>:eolab:dieter:sensoren:sensecap_s2103.pdf}}
 +
 +Datenblatt von [[https://solution.seeedstudio.com|SenseCAP]]
 +
 +===== Kommentar =====
 +Wie dem Datenblatt entnommen werden kann liegt die maximale Betriebsfeuchtigkeit bei 90%. Der Sensor selber misst selber bereits Feuchtigkeit, welche höher als 90% rH liegen. Daher kann nicht mit 100% Zuverlässigkeit gesagt werden, dass die Sensordaten in diesem Fall der Realität entsprechen. Zur Überprüfung dieses Falls muss ein Vergleich zu einem teureren Sensor angestellt werden.
  
eolab/dieter/sensoren/sc-s2103.1729008998.txt.gz · Last modified: 2024/10/15 18:16 by jan.sonntag