User Tools

Site Tools


amc2020:group_n:sn74hc595n

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
amc2020:group_n:sn74hc595n [2020/07/18 19:36] jonas001amc2020:group_n:sn74hc595n [2021/08/24 17:35] (current) – external edit 127.0.0.1
Line 1: Line 1:
 +<html>
 +  <left>
 +    <a href="https://wiki.eolab.de/doku.php?id=amc2020:group_n:start"; onmouseover="style.color='green'";>
 +      <span style="color:#2E71B8"; onmouseover="style.color='green'"; onmouseout="style.color='#2E71B8'";>
 +        &#8617 Back to the main page
 +      </span>
 +    </a>
 +  </left>
 +</html>
 +
 ====== SN74HC595(N) Shift Register ====== ====== SN74HC595(N) Shift Register ======
  
Line 52: Line 62:
 | Operating Temperature  | -40 – 125 °C                 | | Operating Temperature  | -40 – 125 °C                 |
 | Power consumption      | 80 μA (max at 6V)            |  | Power consumption      | 80 μA (max at 6V)            | 
 +
 +Further information can be found in the {{https://www.ti.com/lit/ds/symlink/sn74hc595.pdf?ts=1595095743394&ref_url=https%253A%252F%252Fwww.google.de%252F|SN74HC595 datasheet}}.
  
 ^ **//Table 2 //** SN74HC595(N) pin overview and description  ^^^^ ^ **//Table 2 //** SN74HC595(N) pin overview and description  ^^^^
Line 137: Line 149:
 ===== 4.3 Combining the Sketches ===== ===== 4.3 Combining the Sketches =====
  
-This code can be combined with the code from the DHT-22 and the DS18B20s. This way the sensors are only powered when they are supposed to measure and are switched off again afterwards.+This code can be combined with the code from the DHT-22 and the DS18B20s such that the sensors are only powered when they are supposed to measure and are switched off again afterwards.
  
-The sensors and the shift register need to be connected like explained in their pages, respectively. Additionally, the VDD pin of the DHT-22 must be connected to QB of the shift register and the VDD of both DS18B20s must be connected to QC. Furthermore, if a red LED with a 330Ω resistor in series is connected to QA, it indicates when the sensors finish their measurements with a short blink.+The sensors and the shift register need to be connected like explained in their pages, respectively. Additionally, the VDD pin of the DHT-22 must be connected to QB of the shift register and the VDD of both DS18B20s must be connected to QC. Furthermore, if a red LED with a 330Ω resistor in series is connected to QA, it indicates when the sensors finish their measurements with a short blink (figure 3). 
 + 
 +^{{:amc2020:group_n:esp32_all_sensors_breadboard.png?direct&800|Figure 3}}^ 
 +|**//Figure 3//** ESP32 connected with DHT-22, DS18B20 and SN74HC595.|
  
 ==== 4.3.1 The Code combined ==== ==== 4.3.1 The Code combined ====
Line 370: Line 385:
  
 During this test, all sensors were in equilibrium, measuring the room temperature during a rather hot summer day, and all results are close together, indicating that the sensors are working properly. During this test, all sensors were in equilibrium, measuring the room temperature during a rather hot summer day, and all results are close together, indicating that the sensors are working properly.
 +
 +<html>
 +  <center>
 +    <span>
 +    <a href="javascript:self.scrollTo(0,0)"; onmouseover="style.color='green'";>
 +      <span style="color:#2E71B8"; onmouseover="style.color='green'"; onmouseout="style.color='#2E71B8'";>
 +        Back to the top &#10548
 +      </span>
 +    </a>
 +    </span>
 +  </center>
 +</html>
amc2020/group_n/sn74hc595n.1595093804.txt.gz · Last modified: 2021/08/24 17:34 (external edit)